THE TONGXING COLLECTION

Air-cooled modular chillers

Cooling that grows with you.

Compare published chiller specifications.

Use the catalogue values below to prepare a shortlist. Confirm rating conditions, performance at your design water and outdoor temperatures, and the current configuration before ordering.

Published catalogue data for the available models
Parameter65 kW Air-Cooled Modular Chiller130 kW Air-Cooled Modular Chiller260 kW Air-Cooled Modular Chiller
ModelCLS-F65HW/ZR1BCLS-F130HW/ZR1BCLS-F260HW/ZR1B
Cooling capacity65 kW130 kW260 kW
Heating capacity70 kW132 kW262 kW
Power supply380–415 V / 3N / 50 Hz380–415 V / 3N / 50 Hz380–415 V / 3N / 50 Hz
Cooling power input20.6 kW39.8 kW78.3 kW
Heating power input21.3 kW40.8 kW80 kW
RefrigerantR410AR410AR410A
Compressor typeScrollScrollScroll
Number of compressors248
Net dimensions (W × H × D)2000 × 1920 × 900 mm2200 × 2220 × 1100 mm3800 × 2130 × 2000 mm
Net weight610 kg1010 kg2450 kg
Discuss this modelRequest technical selectionRequest technical selectionRequest technical selection

Electrical supply and nominal capacity describe the published configuration. For a different supply frequency, voltage or duty, request a separate selection. This table does not establish availability or market approval for your destination.

Prepare your chiller selection brief

Tongxing supplies air-cooled modular chillers for commercial chilled-water systems. The published range includes 65, 130 and 260 kW models. Compare the individual specifications below and ask our team to select equipment for your project conditions.

Start with the system requirements

Provide the required cooling and heating duties, entering and leaving water temperatures, design outdoor temperature and available electrical supply. Building area alone is not enough to confirm a chiller selection. Existing fan coils, air handling units, pumps and controls also need to be considered.

Compare the available models

The CLS-F65HW/ZR1B, CLS-F130HW/ZR1B and CLS-F260HW/ZR1B catalogue models list 65, 130 and 260 kW cooling capacities respectively. Their published supply is 380–415 V, three-phase with neutral, 50 Hz. Ask for a separate selection if your project has different power or operating conditions. Catalogue capacity is a starting point, not a guarantee at every site condition.

Plan installation and ongoing operation

Share the proposed installation location, access route, available footprint, noise requirements and maintenance arrangements. If you are considering several modules, ask our team to confirm the proposed combination, hydraulic design, controls and service access for those exact models.

Request technical selection and a quotation

Tell us the project country, required quantity, preferred delivery schedule and any required certification documents. Tongxing can discuss equipment selection and installation guidance; the quotation will confirm the agreed equipment and scope.

EQUIPMENT BUYER’S BRIEF

Air-cooled chiller procurement for commercial projects

For a new chilled-water system, a modular plant expansion or a commercial chiller replacement, identify the equipment scope before requesting a price. Tongxing can discuss the published models against your project brief.

What is an air-cooled chiller?

An air-cooled chiller supplies chilled water and rejects heat to outdoor air through its condenser. The building still needs a coordinated water circuit and terminal equipment. For a commercial chiller enquiry, state the required water temperatures and site conditions as well as capacity.

How much does an air-cooled chiller cost?

A project price depends on the selected duty, configuration, quantity and supply scope. Ask for an itemised equipment quotation and identify pumps, controls, freight and site work separately. A published capacity alone is not enough to quote a complete chilled-water system.

New plant or modular expansion?

For a new plant, separate chillers from pumps, water treatment, distribution pipework and site controls in the enquiry. For expansion, provide the existing module schedule and control sequence. Ask how the proposed equipment will be coordinated with the installed plant; matching nominal capacity does not establish compatibility.

How should I compare chiller quotations?

Compare each selection at the same leaving-water temperature, outdoor temperature and fluid conditions. Request the proposed model, available capacity, input power and included accessories at the specified duty. A low equipment price is not a like-for-like comparison if pumps, controls or delivery scope differ.

What is needed for a replacement chiller quote?

Send the existing nameplate, water connections, installation footprint, electrical supply and access constraints. State the required outage window and who will manage the changeover. Your local engineer should confirm whether the original design duty still represents the building’s needs.

Request a project equipment quotation

YOUR NEXT PROJECT STARTS HERE

Great spaces.
Start with a conversation.

Let’s build your solution